Owner’s Manual
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS
SHOULD ATTEMPT INSTALLATION!!
This manual should remain with the unit.
Liquid-cooled, Prepackaged
Standby Generators
Model Number: 005031-2 (25kW)
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - Owner’s Manual

Owner’s ManualONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!!This manual should remain with the unit.Liquid-cooled, Prepackag

Strany 2 - 1-800-333-1322

8  Any attempt to crank or start the engine before it has been properly serviced with the recom-mended oil may result in an engine failure.1.14 COO

Strany 3

92.1.2 OTHER PUBLISHED STANDARDSIn addition to NFPA standards, the following informa-tion pertaining to the installation and use of standby electric

Strany 4 - WARNING:

10 2.5 EMERGENCY CIRCUIT ISOLATION METHODThis prevents overloading the generator by keeping electrical loads below the wattage/amperage capac-ity of

Strany 5 - EXPLOSION HAZARDS

11• The control board WILL monitor all engine condi-tions and shut down on all the faults listed in this document.Pos2 OFF — ATS Application• The

Strany 6

12 Section 3 - OperationLiquid-cooled 25 kW GeneratorsWhen using maintenance-free batteries, it is not necessary to check the specific gravity or ele

Strany 7 - 1.6 GENERATOR FUEL SYSTEM

13• After the engine starts and when the generator AC output voltage and frequency have reached a pre-set value, transfer switch circuits signal the

Strany 8 - 1.10 SPECIFICATIONS

14 3.2.3 15 AMP FUSEThis fuse protects the control console’s DC control circuit against electrical overload and is located inside the control panel.

Strany 9 - SYSTEM FOR LP VAPOR

15Section 3 - OperationLiquid-cooled 25 kW GeneratorsThis secondary function is only available with DIP switch two in the OFF position (ATS - automa

Strany 10 - INSTALLATION

16 3.6 AUTOMATIC OPERATIONTo set the system for fully automatic operation, pro-ceed as follows:• Check that load circuits are connected to the utilit

Strany 11 - 2.4 BASIC STANDBY ELECTRIC

17Switch Position 8 — Selects whether the control is in the Normal Mode of operation or Test Mode. In the Normal Mode of operation, pre-determined g

Strany 12 - Pos2 ON — GTS Application

2 INTRODUCTIONThank you for purchasing this model of the QuietSource™ standby generator series.Every effort was expended to make sure that the inform

Strany 13 - 2.10 BATTERY INSTALLATION

18 FIRST 100 OPERATING HOURS1. Change engine oil and oil filter. After initial change, service engine oil and filter at 150 operat-ing hours or six

Strany 14 - 3.1 GTS TRANSFER SWITCH

19 The exhaust system parts from this product get extremely hot and remains hot after shutdown. High grass, weeds, brush, leaves, etc. must remain

Strany 15 - COMPONENTS

20 4.8.7 INSPECT EXHAUST SYSTEMInspect the exhaust system at least once every three months. Check all exhaust system pipes, mufflers, clamps, etc. f

Strany 16

214.9 MISCELLANEOUS MAINTENANCE4.9.1 CLEANING THE GENERATORKeep the generator as clean and as dry as possible. Dirt and moisture that accumulates o

Strany 17

22 Section 4 — MaintenanceLiquid-cooled 25 kW Generators4.10 SCHEDULED MAINTENANCEThe following is a recommended maintenance schedule for small stand

Strany 18 - SETTINGS

23Section 4 — MaintenanceLiquid-cooled 25 kW Generators Maintenance Level 1 Level 2 Level 3 Level 4 Tasks Recom- Task Required Task Req

Strany 19 - ADJUSTMENT

24 Section 4 — MaintenanceLiquid-cooled 25 kW Generators Maintenance Level 1 Level 2 Level 3 Level 4 Tasks Recom- Task Required Task Requi

Strany 20 - 4.5 COOLING SYSTEM

25Section 5 — TroubleshootingLiquid-cooled 25 kW GeneratorsTROUBLESHOOTING POINTSPROBLEM CAUSE CORRECTIONEngine won’t crank. 1. 15 amp fuse blown

Strany 21 - OPERATOR CAN PERFORM

26 Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsWiring Diagram — 2.5L Engine (15kW & 20kW units) —Drawing No. 0F2183-B

Strany 22 - (0.042 - 0.046 inch)

27Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsWiring Diagram — 2.5L Engine (15kW & 20kW units) —Drawing No. 0F2183-B

Strany 23 - 4.9 MISCELLANEOUS MAINTENANCE

Table of ContentsLiquid-cooled 25 kW Generators 1INTRODUCTION ... IFCRead this Manual Thoroughly ...

Strany 24 - 4.10 SCHEDULED MAINTENANCE

28 Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsElectrical Schematic — 2.5L Engine (15kW & 20kW units) —Drawing No. 0F2184-B

Strany 25

29Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsElectrical Schematic — 2.5L Engine (15kW & 20kW units) —Drawing No. 0F2184-B

Strany 26

30 Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsWiring Diagram — 2.5L Engine (25kW unit) —Drawing No. 0F1286-B

Strany 27 - TROUBLESHOOTING POINTS

31Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsWiring Diagram — 2.5L Engine (25kW unit) —Drawing No. 0F1286-B

Strany 28 - Section 6 - Electrical Data

32 Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsElectrical Schematic — 2.5L (25kW unit) — Drawing No. 0F1287-B

Strany 29

33Section 6 - Electrical DataLiquid-cooled 25 kW GeneratorsElectrical Schematic — 2.5L (25kW unit) — Drawing No. 0F1287-B

Strany 30

34 Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 kW GeneratorsMounting Base — Drawing No. 0F0104-B

Strany 31

35Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 kW GeneratorsMounting Base — Drawing No. 0F0104-BITEM PART NO. QTY. DESCRIPTION 1 0F17

Strany 32

36 Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 kW GeneratorsEnclosure — Drawing No. 0F1645-HSTATES FOAM IS ON NEAR SIDE STATES FOAM IS

Strany 33

37ITEM PART NO. QTY. DESCRIPTION 1 0F0783 1 DUCT INTAKE MID AL 2.5L 2 0F0781 1 DUCT DISCHARGE RH AL 2.5L 3 0F0780 1 DUCT DISCHARGE LH AL

Strany 34

2 Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the

Strany 35

38 Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 kW GeneratorsControl Panel (15kW and 20kW) — Drawing No. 0F2267-D

Strany 36

39ITEM PART NO. QTY. DESCRIPTION 1 0F0790 1 TOP, CONTROL PANEL 2 0F0789 1 BACK & BOTTOM, CONTROL PANEL 3 0F0791 1 PANEL, FRONT 2.5L C

Strany 37

40 33324033413261216313912291224251215148332438122363435322130414111742121222018431272857Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 k

Strany 38 - TYPICAL OF ROOF PANEL THAT

41ITEM PART NO. QTY. DESCRIPTION 1 0F0790 1 TOP, CONTROL PANEL 2 0F0789 1 BACK & BOTTOM, CONTROL PANEL 3 0F0791 1 PANEL, FRONT 2.5L

Strany 39

42 815661614194130202760203029285939521938392040225417131519FOR HARNESSGROUND532217681519103822310HSG.2034745204911639503435653357183718201638RADIATO

Strany 40

43ITEM PART NO. QTY. DESCRIPTION 1 0E9909 REF ENGINE 2.5L FORD 2 0E9739 1 PULLEY, 2.5L FORD WATER PUMP 3 049814 8 SCREW HHC M10-1.5 X

Strany 41

44 PORT"OUT 1"22721TO ENGINE1042COVERTO VALVE1213281820333132173426638301625241842915952764CARBURETOR ASSY.0E1028A (I/N 19)CONVERSION3541&q

Strany 42

45ITEM PART NO. QTY. DESCRIPTION 1 0E8456 1 BRACKET FUEL REGULATOR 2 075580 1 FLANGE FUEL INLET 3 0E9967 1 ASSY FUEL REG 2.5L FRD N/G-L/P

Strany 43

46 3LOCKTIGHTLOCKTIGHT7151787618416LEADS529132119201410111230131Section 7 - Exploded Views and Parts ListsLiquid-cooled 25 kW GeneratorsAlternator —

Strany 44 - Engine — Drawing No. 0E9918-F

47ITEM PART NO. QTY. DESCRIPTION 1 0F1659A 1 ROTOR 390 15KW 1P DIRECT HSB (2.5L FORD) 0F1657A 1 ROTOR 390 20KW 1P DIRECT HSB (2.5L FORD)

Strany 45

3• Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK

Strany 46

ITEM PART NO. QTY. DESCRIPTION 1 0F2912 1 PIPE MUFFLER OUT 2 0F2869 1 PIPE EXHAUST 2.5L FORD 3 0F2823 1 MUFFLER 2.5L FORD 4 036434 2

Strany 47

49ITEM PART NO. QTY. DESCRIPTION 1 098290 1 ASM MOTOR STEPPER 2 098941A 1 HOUSING GOVERNOR CONNECTOR 3 0F0454 REF HARN GOV 2.5L FORD 4

Strany 48

50 ITEM PART NO. QTY. DESCRIPTION 1 0E9769 REF SUPPORT RADIATOR 2.5L FORD 0F0779 REF SUPPORT RADIATOR 2.5L AL 0E9769A REF SUPPORT RA

Strany 49

51Section 8 — Installation DiagramLiquid-cooled 25 kW GeneratorsInstallation Diagram — Drawing No. 0F1022-A

Strany 50

52 CALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY RIGHTS AND OBLIGATIONSThe California Air Resources Board (CARB) and Generac Power Syst

Strany 51

53Section 9 – WarrantyLiquid-cooled 25 kW GeneratorsEMISSION CONTROL SYSTEM WARRANTYEmission Control System Warranty (ECS Warranty) for 1995 and lat

Strany 52 - TUBE (ON BLOCK)

Part No. 0F5097 Revision D (07/19/05) Printed in U.S.A.Section 9 – WarrantyLiquid-cooled 25 kW GeneratorsGENERAC POWER SYSTEMS "TWO YEAR" LI

Strany 53

4 1.1 GENERATORThis equipment is a liquid-cooled, engine-driven generator set. The generator is designed to supply electrical power that operates cri

Strany 54

51.6 GENERATOR FUEL SYSTEMThis unit has been factory tested and adjusted using a natural gas fuel system. If propane (LP) gas is pre-ferred, refer t

Strany 55 - Section 9 – Warranty

6 Figure 1.6 - Low Coolant Level Sensor1.7.4 OVERSPEED SHUTDOWNShould AC frequency exceed about 72 Hz, cir-cuit board action will automatically shutd

Strany 56 - WARRANTY SCHEDULE

1.10.2 GENERATOR* Rated power of generator is subject to and limited by such factors as ambient temperature, altitude, engine condition, and other fa