Generac 0043736 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Generátory Generac 0043736. Generac 0043736 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 64
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
POWER SYSTEMS, INC.
®
®
Owner’s Manual
Liquid-cooled, Prepackaged
Standby Generators
Models: 0043736
(40 kW/Single-phase w/
200 Amp Transfer
Switch)
0046265
(40 kW/Single-phase w/
200 Amp Transfer
Switch California
Emissions)
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT
INSTALLATION!!
DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY!
This manual should remain with the unit.
Not intended for use in critical life support applications.
!
!
Zobrazit stránku 0
1 2 3 4 5 6 ... 63 64

Shrnutí obsahu

Strany 1 - Owner’s Manual

POWER SYSTEMS, INC.®®Owner’s ManualLiquid-cooled, Prepackaged Standby GeneratorsModels: 0043736(40 kW/Single-phase w/200 Amp TransferSwitch)0046265(40

Strany 2 - 1-800-333-1322

8 Generac®Power Systems, Inc.If an open bottom is used, the engine-generator isto be installed over non-combustible materialsand should be located suc

Strany 3 - Power Systems, Inc. 1

Generac®Power Systems, Inc. 9Figure 2.1 – Basic Standby Electric System2.2 EMERGENCY CIRCUIT ISOLATIONMETHODThis method prevents overloading the gener

Strany 4 - WARNING:

10 Generac®Power Systems, Inc.2.7 BATTERY INSTALLATIONStandby generators installed with automatic trans-fer switches will crank and start automaticall

Strany 5 - EXPLOSION HAZARDS

2.8 PREPARATION BEFORE START-UPThe instructions in this section assume that the standbygenerator has been properly installed, serviced, tested,adjuste

Strany 6 - 1.1.1 LIFTING THE GENERATOR

12 Generac®Power Systems, Inc.3.1 CONTROL CONSOLE COMPONENTSThe components of a liquid-cooled generator controlconsole (Figure 3.1) are as follows:Fig

Strany 7 - 1.8 SPECIFICATIONS

3.2.2 “OFF” POSITIONThis switch position shuts down the engine. This posi-tion also prevents operation.3.2.3 “MANUAL” POSITIONSet the switch to MANUAL

Strany 8 - AND RECOMMENDATIONS

Figure 3.2 – Engine Block HeaterRefer to applicable wiring diagram(s) and electricalschematic(s) at the back of this manual for wiring con-nections.3.

Strany 9 - 1.12 EMISSIONS CONTROL SYSTEM

4.2 CHANGING THE ENGINE OIL ANDFILTER4.2.1 ENGINE OIL RECOMMENDATIONSUse oil of API Service Class SG, SH or SJ. The recommended oil grade for the engi

Strany 10 - OTHER PUBLISHED STANDARDS

16 Generac®Power Systems, Inc.4.4 SPARK PLUGSReset the spark plug gap or replace the spark plugs asnecessary. See Section 4.12.1. Clean the area aroun

Strany 11 - Power Systems, Inc. 9

Generac®Power Systems, Inc. 174.7 OVERLOAD PROTECTION FORENGINE DC ELECTRICAL SYSTEMEngine cranking, start-up and running are controlled bya solid-sta

Strany 12 - 2.7 BATTERY INSTALLATION

Generac®Power Systems, Inc.INTRODUCTIONThank you for purchasing the Guardian product lineby Generac Power Systems. This model is a compact,high perfor

Strany 13 - Power Systems, Inc. 11

18 Generac®Power Systems, Inc.4.11 OUT OF SERVICE PROCEDURE4.11.1 REMOVAL FROM SERVICEIf the generator cannot exercise every seven days, and itis to b

Strany 14 - Power Systems, Inc

Generac®Power Systems, Inc. 19Section 4 — MaintenanceGuardian Liquid-cooled 40 kW Generator4.12 SERVICE SCHEDULEATTENTION: It is recommended that all

Strany 15 - 3.4 SEQUENCE OF AUTOMATIC

20 Generac®Power Systems, Inc.Section 5 — TroubleshootingGuardian Liquid-cooled 40 kW Generator5.1 TROUBLESHOOTING GUIDEPROBLEM CAUSE CORRECTIONThe en

Strany 16 - 3.6 WEEKLY EXERCISE CYCLE

Generac®Power Systems, Inc. 21Section 6 — Installation DiagramGuardian Liquid-cooled 40 kW GeneratorDrawing No. 0E7015

Strany 17 - 4.3 CHANGING THE ENGINE AIR

S16S150002191502291413791415151568456856986TS1HZ - FREQUENCY METERHZTB1 - TERMINAL BLOCKSLEGENDGCBGCB - GOVERNOR CONTROL BOARDBLUEBLUEREDBLACKP/N 986

Strany 18 - 4.6 COOLING SYSTEM

Generac®Power Systems, Inc. 23ACTUATORBROWNORANGEYELLOWBLACKN.C.TO GOVERNORHMCPEHTS1, TS2 - TERMINAL STRIPSLPC - LOWER PANEL CONNECTIONTS2R1 - RESIST

Strany 19 - 4.9 ENGINE COOLANT

AAMVML11512356241BA1711321657D14119CAPE34TO LOWER PANEL (CONNECTOR CP)UJBTSWVHXOGANQMEKFCD4510123TO ENGINE (CONNECTOR EH)61112117+219153181614-+-+-CON

Strany 20 - 4.11 OUT OF SERVICE PROCEDURE

Generac®Power Systems, Inc. 25S15N00P178KMS123N2N1T1SRT2X194GFBE6S16215758S3N1N2T223194CUSTOMER CONNECTIONCUSTOMER CONNECTION120/240V. 1-PHASEE1 TO E

Strany 21 - 4.12 SERVICE SCHEDULE

N.C.EHHMCP8556BLACKAVR1413148556850465N2N114131414138508556REDPFC148585644BLACKTR1BLUEBLACKBLUEREDBLUE239T2T1225A015CT2T117815E1485176L1-S16229S1515T2

Strany 22 - 5.1 TROUBLESHOOTING GUIDE

Generac®Power Systems, Inc. 27BJXWSTVUAONMQFKGHECD5436CAPL189121011127PSW - SWITCH, PHASE SELECTORSW2 - SWITCH, SET EXERCISE SW1 - SWITCH, AUTO/OFF/MA

Strany 23 - Drawing No. 0E7015

Table of ContentsGuardian Liquid-cooled 40 kW GeneratorGenerac®Power Systems, Inc. 1Introduction ...Inside Front CoverRead This M

Strany 24 - Section 7 — Electrical Data

(-)(+)(+)12312EC1OS**FSWHITEEHGREENBLACKLEGEND:ONLY USED ON EMISSIONS MODELS12131110895762431BAT13ALT13BLACKGND013*SM16REDRED16BAT:EC1:CC:EH:FS:GND:IC

Strany 25 - Section 6 — Electrical Data

Generac®Power Systems, Inc. 29TCALTID(+)(-)14ACT*012V BATTERY0HCT85WLS0160161CCMP185*LOSFS1611605679/CLEAR0/BARE0/BLACK08508501479131412386457EC110912

Strany 26

30 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts ListsGuardian Liquid-cooled 40 kW GeneratorsMounting Base - Drawing No. 0E697626243

Strany 27

Generac®Power Systems, Inc. 31ITEM PART NO. QTY. DESCRIPTION1 0E6900 1 MTG BASE 4.3L D/D PRE-PACK2 038804T 1 CABLE BATT RED #1 X 31.003 055414 1 LUG S

Strany 28

32 Generac®Power Systems, Inc.22FRAMEBASE32911336253031142429232618515393433321212119281819610517295111311102142167Section 8 — Exploded Views and Part

Strany 29

Generac®Power Systems, Inc. 33ITEM PART NO. QTY. DESCRIPTION1 0C3594 10 ASSEMBLY M6 HINGE3 0A3359 40 SCREW BHSC M6-1.0 X 16 SS4 0A3360 40 SHAKEPROOF I

Strany 30

34 Generac®Power Systems, Inc.531214VIEW A-A1718162019515239318151352535935565455565741184950216436263760AA9515253602343294261612428254127504945463INS

Strany 31

Generac®Power Systems, Inc. 35ITEM PART NO. QTY. DESCRIPTION1 0D5488 1 PANEL BTM & BACK CONTROLPANEL2 0D1521A 1 CONTROL PANEL, FRONT W/ SILKSCREEN

Strany 32 - 30 Generac

36 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts Lists(Model No. 0046262, 0046263 & 0046264) Guardian Liquid-cooled 40 kW Genera

Strany 33 - Power Systems, Inc. 31

Generac®Power Systems, Inc. 37ITEM PART NO. QTY. DESCRIPTION1 0D7397 1 PNL BTM & BACK CNTL PNL 046262 0D1521A 1 CONTROL PANEL FRONT W/ SILKSCREEN3

Strany 34 - 32 Generac

2 Generac®Power Systems, Inc.Study these SAFETY RULES carefully before installing,operating or servicing this equipment. Become familiarwith this Owne

Strany 35 - Power Systems, Inc. 33

38 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts ListsGuardian Liquid-cooled 40 kW GeneratorsConnection Box – Drawing No. 0E6892-A

Strany 36 - 34 Generac

Generac®Power Systems, Inc. 39Section 8 — Exploded Views and Parts ListsGuardian Liquid-cooled 40 kW GeneratorsConnection Box – Drawing No. 0E6892-AIT

Strany 37 - Power Systems, Inc. 35

40 Generac®Power Systems, Inc.1521SCROLL DETAILTHREAD IN SENSOR (6) UNTIL CONTACTIS MADE WITH RING GEAR, THEN BACK OFF1/2 TO 3/4 TURN AND TIGHTEN NUT.

Strany 38 - 36 Generac

Generac®Power Systems, Inc. 41Section 8 — Exploded Views and Parts ListsGuardian Liquid-cooled 40 kW GeneratorsGenerator – Drawing No. 0E6891ITEM PART

Strany 39 - Power Systems, Inc. 37

42 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts ListsGuardian Liquid-cooled 40 kW GeneratorsEngine – Drawing No. 0D6980-B

Strany 40 - 38 Generac

Generac®Power Systems, Inc. 43ITEM PART NO. QTY. DESCRIPTION1 0A9046 1 ENGINE 4.3L GM2 0A9118A 1 FLYWHL 4.3L GM SAE3 070022 1 WASHER STAR M12 EXT4 0A6

Strany 41 - Power Systems, Inc. 39

44 Generac®Power Systems, Inc.1240246313237344202345434022783613510113319314353341430284427912143254640412617163815472Section 8 — Exploded Views and P

Strany 42 - LL DETAI

Generac®Power Systems, Inc. 45ITEM PART NO. QTY. DESCRIPTION1 0A9046 1 ENGINE 4.3L GM2 0A4084 2 MOUNT, ENGINE (R & L)3 0A4239 1 PULLEY CRANKSHAFT4

Strany 43 - Power Systems, Inc. 41

17KIT PART NO. 0D7947201819KIT PART NO. 0D7948303133353432379101114163938362740291101627"A"221537242223TO "A"KIT PART NO. 0D812110

Strany 44 - Engine – Drawing No. 0D6980-B

Generac®Power Systems, Inc. 47ITEM PART NO. QTY. DESCRIPTION1 0D7825 1 RADIATOR COPPER BRASS2 0D8251 1 FAN GUARD BOTTOM3 0D8252 1 FAN GUARD TOP4 02465

Strany 45 - Power Systems, Inc. 43

Generac®Power Systems, Inc. 3• Inspect the generator regularly, and promptly repairor replace all worn, damaged or defective parts usingonly factory-a

Strany 46 - Engine – Drawing No. 0A4304-L

ITEM PART NO. QTY. DESCRIPTION1 059902A 1 CAP RAIN 2.50 / 2.692 0C9641 1 TUBE STRAIGHT 'A' GROUP3 0C9650 1 MUFFLER 2-1/2" INLET/OUTLET4

Strany 47 - Power Systems, Inc. 45

Generac®Power Systems, Inc. 49ITEM PART NO. QTY. DESCRIPTION1 037561 1 NUT WING 1/4-20 NYLK2 0A4632A 1 PLATE AIR CLEANER TOP3 0A4637 1 FILTER AIR 11.5

Strany 48 - 46 Generac

Section 8 — Exploded Views and Parts Lists(Model No. 0043733, 0043734 & 0043735) Guardian Liquid-cooled 40 kW Generators4.3L Nat. Gas Fuel System

Strany 49 - Power Systems, Inc. 47

Generac®Power Systems, Inc. 51ITEM PART NO. QTY. DESCRIPTION1 065907 1 SUPPORT SOLENOID NAT GAS2 026812 3 ELBOW 90D 3/4 NPT3 028238 2 BOLT U 5/16-18 X

Strany 50 - 48 Generac

52 Generac®Power Systems, Inc.2436MANIFOLDTO INTAKE3822394333123031441344035292837COVERTOVALVEATTACH TOFAN SCROLLASSEMBLYP/N 0D35092133122442517202241

Strany 51 - Power Systems, Inc. 49

Generac®Power Systems, Inc. 53ITEM PART NO. QTY. DESCRIPTION1 065907 1 SUPPORT SOLENOID NAT GAS2 026812 3 ELBOW 90D 3/4NPT3 022259 4 NUT HEX 5/16-18 S

Strany 52 - 50 Generac

54 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts Lists(Model No. 0046262, 0046263 & 0046264) Guardian Liquid-cooled 40 kW Genera

Strany 53 - Power Systems, Inc. 51

Generac®Power Systems, Inc. 55ITEM PART NO. QTY. DESCRIPTION1 059902A 1 CAP RAIN 2.50 / 2.692 0C9641 1 TUBE STRAIGHT 'A' GROUP3 0D4208 1 MUF

Strany 54 - 52 Generac

56 Generac®Power Systems, Inc.Section 8 — Exploded Views and Parts Lists(Model No. 0043733, 0043734 & 0043735) Guardian Liquid-cooled 40 kW Genera

Strany 55 - Power Systems, Inc. 53

Generac®Power Systems, Inc. 57ITEM PART NO. QTY. DESCRIPTION1 0C4905 1 BARBED EL 45 FITTING2 057822 2 CLAMP HOSE #8 .53-1.003 077043E 1 CONDUIT FLEX 1

Strany 56 - 54 Generac

4 Generac®Power Systems, Inc.1.1 UNPACKING/INSPECTIONAfter unpacking, carefully inspect the contents for dam-age. • This standby generator set has bee

Strany 57 - Power Systems, Inc. 55

58 Generac®Power Systems, Inc.Section 9 – NotesGuardian Liquid-cooled 40 kW Generators

Strany 58 - 56 Generac

Generac®Power Systems, Inc. 59Section 9 – NotesGuardian Liquid-cooled 40 kW Generators

Strany 59 - Power Systems, Inc. 57

60 Generac®Power Systems, Inc.Section 10 – WarrantyGuardian Liquid-cooled 40 kW GeneratorsCALIFORNIA EMISSION CONTROL WARRANTY STATEMENTYOUR WARRANTY

Strany 60 - Section 9 – Notes

Generac®Power Systems, Inc. 61Section 10 – WarrantyGuardian Liquid-cooled 40 kW GeneratorsEMISSION CONTROL SYSTEM WARRANTYEmission Control System Warr

Strany 61

Part No. 0E7018 Revision A (10/08/03) Printed in U.S.A.Section 10 – WarrantyGuardian Liquid-cooled 40 kW GeneratorsGENERAC POWER SYSTEMS STANDARD &quo

Strany 62

1.6 MAIN CIRCUIT BREAKERThe generator’s main circuit breaker is included with theunit as shipped from the factory. The breaker for eachunit is describ

Strany 63 - Section 10 – Warranty

6 Generac®Power Systems, Inc.1.8.2 GENERATOR AND LOAD COMPATIBILITYThe generator must be fully compatible with the ratedvoltage, number of phases and

Strany 64 - WARRANTY SCHEDULE

1.10 ENGINE OIL RECOMMENDATIONSThe unit has been filled with 15W-40 engine oil at thefactory. Use a high-quality detergent oil classified “ForService